Queensland homes · before 1 January 2027
Deadline: 1 January 2027
When one alarm sounds,
they all sound
Photoelectric, interconnected smoke alarms in every bedroom and hallway — so everyone in the house gets the warning, not just the room that catches first.
Why it matters
It’s not about a sticker on the ceiling
It’s the kids asleep down the hall. The rental you’re turning over. The unit you’re about to list. Queensland’s smoke alarm reforms exist so a fire in one room wakes the whole home — early enough to get out.
Calculating days remaining…
Every bedroom
Alarms where people sleep
Compliant homes put a photoelectric alarm in every bedroom, in the hallway that connects them, and on every storey. When one detects smoke, they all go off — wired or wireless interconnect.
- Photoelectric only (no ionisation-only units)
- Marked AS 3786-2014
- Less than 10 years old and working when tested
Everyday living
Hardwired or 10-year battery
New builds and major renovations need hardwired photoelectric alarms (licensed electrician). Many existing homes can use wireless 10-year non-removable battery units that interconnect without rewiring — still installed to QFD placement rules.
If the house already has hardwired alarms, replacements must stay hardwired.
Who needs them when
The deadline is already here for many jobs
Since 2017
New builds & renovations
Interconnected photoelectric alarms already required.
Since 2022
Sale or lease
Already required when a dwelling is sold, leased or re-leased.
1 Jan 2027
Every remaining home
All other Queensland dwellings must comply — houses, townhouses, units.
Quick check
Upgrade if any of these are true
- Ionisation sensor, or not marked photoelectric
- Alarms are not interconnected
- Older than 10 years, or fail a monthly test
- Missing from bedrooms, connecting hallways, or any storey
- Only a replaceable 9V cell where a sealed 10-year battery is required
Test monthly. Keep exits clear. Practise a home fire escape plan.
South East Queensland
Book a Sintech rep to visit
We’ll come to your premises for a smoke-alarm audit, compliance check, or upgrade quote across the SEQ area. Tell us a little about the property and we’ll be in touch.
Talk to Sintech
Need compliant alarms for a job?
We supply trade and project customers across Queensland — photoelectric interconnected options, hardwired or 10-year battery. Don’t leave it to December.